| Name |
Description |
| EPL Acoustic System |
Assembly comprising two speakers, probe tubes and probe tube microphone used in the EPL Cochlear Function Testing System. |
| EPL Accelerometer Amplifier |
Amplifier designed for use with cheap MEMS accelerometers that run off 9V. For use with VSEPs and etc. |
| EPL Microphone Amplifier |
Microphone amplifier designed for use with the EPL Acoustic System. Versions for FG series and EK series microphones. |
| EPL BioAmp |
In-house amplifier for ABR/CAP and other electrophysiological recording. |
| EPL Fiberoptic Amplifier |
Fiberoptic LED with a stable output and a fiberoptic photodiode with high frequency (~30KHz bw) linear transimpedance amplifier. |
| EPL Photometer |
Free field photometer for measuring optical stimulation |
| EPL Equalizer |
Two-channel filter designed for use with the EPL Acoustic System. |
| EPL Bipolar Current Source |
Current source for driving cochlear implant electrodes. Low DC leakage, monitor output, and lab grade with no batteries required. |
| EPL Monopolar Current Source |
Single-quadrant current source for driving LEDs. It has 3 versions (20mA, 30mA, 300mA) and an optional current monitor output. |
| EPL Valve Driver |
Driver for solenoid valves commonly used in behavioral studies. |
| EPL 2 Grass Adapter |
Adapter from tandard EPL power supply to the Grass Instruments 4 pin power connector common from the late 1970s to early 2010s. |
| EPL Cardiotach |
Heart rate monitor for veterinary use. Includes an LCD read out, integrated windowed warning alarms, and optional linear voltage output. |
| EPL Wearable Microfluidic Pump Hardware and Firmware |
First wearable intracochlear drug delivery pump for subjects of this size. Poster |
| EPL/Ext. Lickometer |
Device used to detect contact with lickspout in behavioral experiments. |
| EPL/TDT Headstage Breakout |
Breakout board for one version of TDT headstage. |
| EPL Differential Amplifier |
Selectable gain, labratory grade (long term stable, precsion), amplifier that can drive a long (40ft) cable. |
| EPL Differential Buffer |
Unity gain differential amplifier that can drive a 40ft cable. Commonly used with the EPL Bipolar Current Sources to monitor the stimuli delivered. |
| EPL Cross Point Switch |
Cross point switch used to multiplex multiple EPL Bipolar Current Sources across an even larger number of implant electrodes via computer control. |
| EPL Subrack and EPL Subrack Module |
Standard rack setup developed from commercially-available subrack. Most of our hardware is compatible with this systems. |